1. introduction: why should we test the reliability of cn2 lines from the us side?
(1) background: cn2 is an optimized backbone network for china telecom. it is often used for high-quality backhaul links from international to china and has a great impact on overseas service quality.(2) objective: service providers, cdn or vps operators exporting from the united states to china need to evaluate the delay, jitter and packet loss of cn2 links to ensure user experience.
(3) tools: traceroute and mtr are common tools for determining paths and real-time packet loss/delay, and are suitable for troubleshooting routing problems and link quality.
(4) correlation technology: the detection results directly affect server deployment, cdn scheduling, ddos protection strategies and bandwidth redundancy decisions.
(5) output expectations: provide quantifiable reliability evaluation indicators and tuning suggestions to facilitate operation, maintenance and product decision-making.
2. test environment and server configuration examples
(1) example of us detection terminal: vps (digitalocean nyc) ip 203.0.113.10, linux ubuntu 22.04, traceroute v2.1.0, mtr v0.94.(2) chinese target example: cn2 computer room host ip 45.120.50.20, the computer room belongs to as4134 (chinanet), web service nginx 1.18, port 443.
(3) test link configuration: icmp/udp detection, ttl from 1 to 30, mtr running time 300 seconds, message size 64 bytes.
(4) network measurement frequency: traceroute + mtr every hour (lasts for 5 minutes), and reports the results to the monitoring platform (prometheus + grafana).
(5) security precautions: during detection, avoid production peaks and comply with the detection strategy of the target network. if necessary, communicate with the other party's operation and maintenance to avoid false positives as ddos.
3. traceroute sample output and table display
(1) command example: traceroute -i -m 30 45.120.50.20 (use icmp to pass through the isp firewall policy).(2) note: the ip and delay of each hop can be used to identify the jump point entering cn2 and whether there is an obvious jump or cross-domain hop.
(3) sample data table (some hops):
| hop | ip | asn | rtt(ms) |
|---|---|---|---|
| 1 | 203.0.113.1 | as6389 | 0.8 |
| 6 | 198.51.100.45 | as3356 | 28.5 |
| 9 | 87.248.112.10 | as174 | 85.2 |
| 12 | 202.97.33.1 | as4134 | 210.6 |
| 14 | 45.120.50.20 | as4134 | 215.1 |
(5) conclusion: if traceroute loses packets or rtt increases sharply after entering as4134, it indicates that there may be congestion or priority policy issues at the cn2 edge or backhaul segment.
4. mtr examples and statistical analysis
(1) command example: mtr -rwzbc 100 45.120.50.20 (run 100 packets to display packet loss and delay).(2) example key output (summary): last hop loss% 2.0%, best 210ms / avg 217ms / worst 240ms / stdev 5.1ms.
(3) key points of hop-by-hop analysis: if the loss% of an intermediate hop is high and the loss% of subsequent hops is low, it means that the intermediate router has a speed limit for icmp but does not affect the actual traffic.
(4) example judgment: if last-hop packet loss >1% or avg rtt >220ms, and jitter (stddev) >10ms within 5 consecutive minutes, the experience is considered to be significantly degraded.
(5) operation suggestions: for hops with persistent packet loss or high latency, submit a work order to the upstream isp and provide the mtr/traceroute timestamp and pcap for easy location.
5. quantitative indicators and thresholds to determine the reliability of cn2 lines
(1) indicator 1: packet loss (packet loss), threshold recommendation: long-term last hop ≤1% is acceptable, 1-3% is a warning, and >3% requires investigation.(2) indicator 2: average latency (avg rtt), threshold recommendation: <=200ms is good, 200-250ms is close to the threshold, and >250ms affects the interactive experience.
(3) indicator 3: jitter (jitter/stddev), threshold recommendation: <=10ms is good, 10-25ms needs optimization, >25ms significantly affects tcp/real-time services.
(4) indicator 4: routing stability (frequency of bgp path changes). if there are >3 path switches within 24 hours, you need to pay attention.
(5) indicator 5: bandwidth and packet loss consistency. use the iperf3 test to confirm whether the throughput is consistent with the icmp indicator to determine whether it is a control plane speed limiter.
6. real case analysis and optimization suggestions (including server configuration examples)
(1) real case: a us cdn node to the cn2 target experienced 4% packet loss during working hours. the mtr pointed to the cn2 edge router (as4134) was a high packet loss point. after communicating with the domestic computer room, it was confirmed that it was edge peak congestion.(2) processing process: provide traceroute (including timestamp) and mtr reports to the domestic communication party. the as peer schedules the traffic project within 6 hours, and the packet loss is reduced to 0.5%.
(3) server configuration example: source station nginx optimization - worker_processes auto, keepalive_timeout 65s, tcp_nodelay on, sysctl adjustment: net.ipv4.tcp_tw_reuse=1, net.core.rmem_max=33554432.
(4) redundancy and strategy: deploy dual exits (directly connected to cn2 and ordinary international links), and use gslb or cdn health detection strategies to switch back based on packet loss/delay.
(5) ddos and line protection: enable upstream cleaning, rate limiting and syn cookies for periods of sudden jitter or large-scale packet loss; and add threshold alarms (packet loss > 1.5% or avg rtt > 230ms) to monitoring.

- Latest articles
- Where Can I Buy Stable Japanese Cn2 Sour Yogurt? Teach You Purchasing And Speed Testing Skills
- Performance Evaluation Korean Mobile Virtual Server Bandwidth And Io Performance Test Results
- Use Traceroute And Mtr Examples To Demonstrate How The United States Determines The Reliability Of Cn2 Lines
- Daily Detection, Log Analysis And Rule Optimization Methods For Operating And Maintaining Korean High-defense Station Groups
- Why Are Servers All In Taiwan? Supply Chain And Bandwidth Cost Comparison Examples
- Purchasing Guide Explains Which Cloud Server Is Best In Malaysia To Support E-commerce And Media Selection Strategies
- User Experience Report Hong Kong Cn2 Telecom Direct Connection Stability And Connectivity Evaluation
- Sharing Of Shenwu Malaysia Server Team Formation And Activity Strategies From The Perspective Of Guild Operations
- The U.s. And European Vps Image Storage Strategy Is Combined With Cdn To Improve Display Efficiency
- How To Improve The Speed And Stability Of Cross-border Access Through Bgp High-defense Us Servers
- Popular tags
Cloud Acceleration
Operator Comparison
Limitations
VPS Speed Comparison
CN2VPS
Uu Accelerator
User Requirements
Mobile Network
Bitcoin
Best Practices
Linode Singapore
Over The Firewall
Network Latency
Singapore Vps Server
Cn2gia Stability Comparison
Low-budget Acceleration Options
Physical Server
Cf Game
Data Backup
Cn2 Server Purchase
App
Client Configuration
Best Service Provider In 2023
Plan
Email IP Settings
Singapore Server Cn2
Address Query
Vps Optimization
Sydney
Native VPS
Related Articles
-
What Is The Fastest Speed Of The US CN2 Line?
This article discusses the fastest speed and characteristics of CN2 lines in the United States to help readers understand the advantages and applications of the CN2 network. -
Explore The Impact Of Us Cn2 Addresses On Network Speeds
this article explores the impact of us cn2 addresses on network speed, including its advantages, applicable scenarios and selection guide. -
Five Reasons To Choose An Independent Cn2 Server In The United States
explore five reasons for choosing an independent cn2 server in the united states and understand its advantages in performance and security.